Oceanic Dive Computer Pro Plus 2 Manual do Utilizador Página 36

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 35
36
PSI
ATR
O
2
N
2
TO SET - TURN PRESSURE ALARM
(while in the Surface Mode)
Factory set for 00 PSI/BAR (disabled), the Turn Pressure
Alarm can be set to values between 1000 and 3000 PSI (69
to 205 BAR) in increments of 250 PSI (17 BAR).
• Press Both buttons simultaneously, release when SET: 2
appears.
• Press and release the Left (Advance) button, the Units
screen appears with the set point flashing.
• Press the Left (Advance) button 10 more times.
• The graphic trn and Alarm (speaker) icon appear with
the Turn Pressure Alarm value flashing (Fig. 34).
• Press and hold the Right (Select) button to scroll through
the Alarm values in increments of 250 PSI (17 BAR).
• Press the Left (Advance) button to accept the setting and
advance to Set End Pressure Alarm, or press and hold
Both buttons for 2 seconds to revert to Surface Mode.
Fig. 34 - Set Turn Pressure Alarm
Vista de página 35